Introduction
أ 1500 kVA transformer is one of the most commonly used power transformers in industrial and commercial applications. Many buyers search for terms like 1500 kVA transformer price, 1500 kVA transformer specification, 1500 kVA transformer weight, and how many amps is a 1500 kVA transformer before making a purchase decision.
This guide will explain everything in simple terms. You will learn about specifications, current calculation, oil capacity, price range, and how to choose between dry type and oil immersed 1500 kVA transformers.
Quick Answer:
- A 1500 kVA transformer is used for industrial power distribution
- It delivers about 2165A at 400V
- Weight ranges from 2500 kg to 5000 kg
- Oil capacity is around 800–1200 liters
- Price ranges from $8,000 to $35,000
👉 If you are planning to buy, you can also get a factory direct quotation within 24 hours.
Table of Contents
- What Is a 1500 kVA Transformer
- 1500 kVA Transformer Specification
- How Many Amps Is a 1500 kVA Transformer
- 1500 kVA Transformer Weight and Dimensions
- 1500 kVA Transformer Oil Capacity
- 1500 kVA Transformer Price
- Dry Type vs Oil Immersed 1500 kVA Transformer
- Applications of 1500 kVA Transformers
- How to Choose the Right 1500 kVA Transformer
- FAQs
1. What Is a 1500 kVA Transformer
أ 1500 kVA transformer is a medium-capacity transformer used to step up or step down voltage in power distribution systems.
It is widely used in:
- Industrial factories
- Solar power plants
- المباني التجارية
- Data centers
- Infrastructure projects
The term kVA (kilovolt-ampere) represents the apparent power capacity of the transformer.
أ 1500 kVA transformer is a power distribution transformer that can handle up to 1500 kilovolt-amperes of apparent power. It is commonly used in industrial facilities, commercial buildings, and renewable energy systems to step voltage up or down efficiently.

👉 Send your requirements and get a customized transformer solution
2. 1500 kVA Transformer Specification
ال 1.5 MVA transformer specification varies depending on project requirements, but standard configurations are as follows:
Typical Specifications Table
| المعلمة | Value |
|---|---|
| Rated Capacity | 1500 kVA |
| Primary Voltage | 11kV / 33kV |
| Secondary Voltage | 0.4kV |
| Frequency | 50Hz / 60Hz |
| Cooling Method | ONAN / AN |
| Vector Group | Dyn11 / Yyn0 |
| Insulation Class | Class A / F / H |
| Standards | IEC / ANSI |
Key Notes
- Voltage can be customized
- Copper or aluminum winding available
- Tap changer can be added
Most 1.5 MVA transformers are designed according to international standards such as IEC transformer standards to ensure safety reliability and global compatibility.
The standard specification of a 1.5 MVA transformer includes primary voltage (typically 11kV or 33kV), secondary voltage (usually 400V), frequency (50/60 Hz), cooling method (ONAN or AN), and vector group such as Dyn11 or Yyn0. These parameters can be customized based on project requirements.
3. How Many Amps Is a 1500 kVA Transformer
One of the most searched questions is:
How many amps does a 1.5 MVA transformer carry?
Formula
For a three-phase transformer:
I = kVA × 1000 ÷ (√3 × Voltage)
Example Calculations
| الجهد االكهربى | حاضِر |
|---|---|
| 400V | ≈ 2165 A |
| 415V | ≈ 2087 A |
| 11kV | ≈ 78.7 A |
Explanation
- Lower voltage = higher current
- Higher voltage = lower current
he current calculation is based on the standard three phase power calculation formula , which is widely used in electrical engineering.
أ 1.5 MVA transformer produces approximately 2165 amps at 400V and about 78.7 amps at 11kV in a three-phase system. The exact current depends on the operating voltage and can be calculated using a standard formula.
Need help calculating current and cable size?
👉Contact our engineers now
4. 1500 kVA Transformer Weight and Dimensions
ال 1.5 MVA transformer weight depends on design and materials.
Typical Weight Range
| Type | Weight |
|---|---|
| Oil Immersed | 3500 – 5000 kg |
| Dry Type | 2500 – 4000 kg |
Factors Affecting Weight
- Copper vs aluminum winding
- Cooling system
- Tank design
- Insulation material
Dimensions
- Length: 1.5m – 2.5m
- Width: 1.2m – 2.0m
- Height: 1.5m – 2.5m
The weight of a 1.5 MVA transformer typically ranges from 2500 kg to 5000 kg, depending on whether it is a dry type or oil immersed design. Oil transformers are generally heavier due to the tank and insulating oil.

5. 1500 kVA Transformer Oil Capacity
ال oil capacity of a 1.5 MVA transformer is a key parameter for cooling and insulation.
Typical Oil Volume
- 800 to 1200 liters
Why Oil Matters
- Dissipates heat efficiently
- Provides insulation
- Extends transformer life
Additional Insight
More oil usually means:
- Better cooling
- Higher overload capacity
- Longer lifespan
The oil capacity of a 1.5 MVA transformer is usually between 800 and 1200 liters. Transformer oil is used for insulation and cooling, helping to improve efficiency and extend the service life of the equipment.
6. 1500 kVA Transformer Price
ال 1.5 MVA transformer price varies based on multiple factors.
Price Range
| Type | Price |
|---|---|
| Oil Immersed | $8,000 – $20,000 |
| Dry Type | $15,000 – $35,000 |
Factors Affecting Price
- Copper vs aluminum
- Brand and manufacturer
- Standards (IEC / ANSI)
- Accessories (OLTC, protection)
- Shipping cost
Cost Optimization Tips
- Choose aluminum for lower cost
- Select standard voltage levels
- Buy directly from factory
The price of a 1.5 MVA transformer typically ranges from $8,000 to $35,000. Oil immersed transformers are more affordable, while dry type transformers are more expensive due to higher safety and material costs.
👉 Get factory direct price within 24 hours
7. Dry Type vs Oil Immersed 1500 kVA Transformer
Choosing between dry type vs oil immersed 1.5 MVA transformer is important.
Comparison Table
| Feature | Dry Type | Oil Immersed |
|---|---|---|
| Safety | High | Medium |
| Cooling | Air | Oil |
| Maintenance | Low | Medium |
| Cost | High | Lower |
| Installation | Indoor | Outdoor |
Summary
- Dry type: safer, cleaner, indoor use
- Oil type: better cooling, lower cost
The main difference between dry type and oil immersed 1.5 MVA transformers is cooling and safety. Dry type transformers use air cooling and are safer for indoor use, while oil transformers use liquid cooling and offer better efficiency and lower cost.

8. Applications of 1500 kVA Transformers
أ 1.5 MVA transformer is widely used in many industries.
Common Applications
- Manufacturing plants
- Solar energy systems
- Wind farms
- المباني التجارية
- Mining projects
Why It Is Popular
- Balanced capacity
- Flexible configuration
- Suitable for medium loads
These transformers play a key role in modern power distribution systems by ensuring stable and efficient electricity delivery.

9. How to Choose the Right 1500 kVA Transformer
Choosing the correct transformer is critical.
Key Factors
1. Installation Location
- Indoor → Dry type
- Outdoor → Oil immersed
2. Load Type
- Stable load → Standard
- Variable load → Consider cooling
3. Environment
- High temperature → Oil type better
- Fire-sensitive → Dry type
4. Budget
- Limited → Oil transformer
- Premium → Dry transformer
Selection Checklist
- Voltage level
- Cooling method
- Material
- Standards
- Protection system
To choose the right 1.5 MVA transformer, you should consider installation location, load requirements, environmental conditions, and budget. Dry type transformers are ideal for indoor use, while oil immersed transformers are better for outdoor and high-load applications.
👉 Send your project details and get free technical support + quotation
10. FAQs
Q1: How many amps is a 1.5 MVA transformer?
A: A 1.5 MVA transformer delivers approximately 2165 amps at 400V and around 78.7 amps at 11kV. The current varies depending on the voltage level and system configuration.
Q2: What is the oil capacity of a 1.5 MVA transformer?
A: The oil capacity of a 1.5 MVA transformer is typically between 800 and 1200 liters, depending on the design and cooling requirements.
Q3: How much does a 1.5 MVA transformer cost?
A: A 1.5 MVA transformer usually costs between $8,000 and $35,000, depending on whether it is oil immersed or dry type and its specifications.
Q4: What is the weight of a 1.5 MVA transformer?
A: Usually 2500 kg to 5000 kg.
Q5: Which is better, dry type or oil transformer?
A: Dry type is safer, oil type is more cost-effective and efficient.
Conclusion
أ 1.5 MVA transformer is a reliable and widely used solution for industrial and commercial power distribution. Understanding its specification, current, oil capacity, weight, and price will help you make the right decision.
👉 Contact us today for custom design, fast delivery, and competitive pricing