Skip to content Skip to sidebar Skip to footer

1250KVA Dry Type Transformer

1250kVA dry type transformer offers reliable, oil-free power distribution for indoor substations, commercial buildings, and industrial projects.

Description

A 1250kVA dry type transformer is a medium-capacity power transformer designed for indoor and safety-critical applications.
It uses air cooling and solid insulation instead of oil, making it suitable for commercial buildings, industrial facilities, substations, and renewable energy projects where fire safety and low maintenance are required.

As a manufacturer, we supply 1250kVA dry type transformers with stable thermal performance, reliable insulation systems, and compliance with IEC and international standards.

1250kVA Dry Type Transformer Overview

Professional high-resolution image of a standalone 1250KVA Dry Type Transformer, showcasing its robust design, cooling ducts, and terminal panels in a clean environment.
Our Flagship 1250KVA Dry Type Transformer. Engineered for superior performance, safety, and reliability in demanding industrial and commercial applications.

Our 1250KVA dry-type transformer features a fully enclosed design with IP54 protection rating, effectively preventing dust and moisture intrusion to ensure stable operation in harsh environments. Utilizing Class H insulation materials with a temperature resistance of 180°C, it significantly extends equipment service life.

The compact structure saves installation space, making it particularly suitable for confined electrical rooms. The surface is treated with environmentally friendly coating offering excellent corrosion resistance and aesthetic appeal. Operating at below 60 dB noise level, it far exceeds national standards, creating a quiet working environment. Our transformer is especially ideal for hospitals, schools, commercial centers and other applications demanding highest safety and reliability requirements.

 

Detailed Photos

Detailed exploded diagram or cutaway view of a 1250KVA Dry Type Transformer highlighting key internal parts: A-Phase, Phase connection, Copper coil, Epoxy resin shell, Cross flow air cooler.
Precision Engineering Inside Our 1250KVA Dry Transformer. Explore the high-quality components that ensure stable performance and longevity, including vacuum-cast copper coils and advanced cooling systems.

This detailed cutaway diagram reveals the transformer’s internal precision structure:

  • Phase A Winding: Uses 99.99% high-purity electrolytic copper conductors with vacuum pressure impregnation treatment, effectively reducing eddy current losses

  • Phase Connection System: Features double-layer insulation design with inter-phase isolation exceeding 3000V, ensuring safe operation

  • Epoxy Resin Encapsulation: Employing imported epoxy resin material with excellent thermal conductivity and mechanical strength, seismic resistance up to level 9

  • Copper Coil System: Nomex paper insulation, Class F insulation rating, temperature rise controlled within 80K

  • Cross-Flow Cooling System: Unique axial-radial composite ventilation design improves heat dissipation efficiency by 35%
    These detailed design features ensure stability and efficiency during full-load operation.

 

1250kVA Dry Type Transformer Technical Specifications

table {
border-collapse: collapse;
width: 100%;
max-width: 900px;
font-family: Arial, sans-serif;
margin-top: 20px;
}
th, td {
border: 1px solid #cccccc;
text-align: left;
padding: 12px;
}
th {
background-color: #f4f4f4;
color: #333;
}
tr:nth-child(even) {
background-color: #f9f9f9;
}
.header-cell {
font-weight: bold;
width: 40%;
}

ParametersSpecifications / Values
Rated Capacity1250 kVA
Voltage Combination (H.V.)6 / 6.3 / 6.6 / 10 / 10.5 / 11 kV
High Voltage Tapping±2×2.5% / ±5%
Voltage Combination (L.V.)0.4 kV
Connection Group SymbolDyn11 / Yyn0
No-load Loss1420 W
Load Loss (130°C / Rank B)8190 W
Load Loss (155°C / Rank F)8720 W
Load Loss (180°C / Rank H)9335 W
No-load Current0.85%

 

 

Comprehensive table listing the key electrical parameters and performance data for the 1250KVA Dry Type Transformer, including rated capacity, voltage, losses, and current.
1250KVA Dry Type Transformer – Technical Specifications. Review the precise performance metrics, including low no-load loss and high efficiency, ensuring optimal operation for your specific voltage requirements.

Our 1250KVA dry-type transformer delivers exceptional performance parameters:

  • Rated Capacity: 1250kVA with short-term overload capability up to 150%

  • Voltage Combination: High voltage side 10kV(±2×2.5%), low voltage side 0.4kV, customizable per customer requirements

  • Connection Group: Dyn11, effectively suppressing harmonic interference

  • No-load Loss: ≤1420W, 20% lower than national standards, saving approximately $700 annually in electricity costs

  • Load Loss: ≤9500W (at 120°C conditions)

  • No-load Current: ≤0.85%, excellent magnetization characteristics
    All parameters are certified by National Transformer Quality Supervision and Inspection Center, ensuring data reliability.

Key Features and Advantages of 1250kVA Dry Type Transformers

Infographic illustrating the quality assurance pillars for the 1250KVA Dry Type Transformer: rigorous QC testing, a two-year warranty, and local service support.
Uncompromising Quality Assurance for Every 1250KVA Dry Transformer. Our promise is backed by a robust QC system, a solid two-year guarantee, and dedicated local team support.

We have established a comprehensive quality assurance system:

  • QC Testing System: 13 quality inspection procedures including partial discharge test (≤5pC), lightning impulse test, sudden short-circuit test

  • Two-Year Warranty: 24-month extended warranty with lifetime maintenance, 48-hour response time for quality issues

  • Local Service: Service networks in 20 countries worldwide providing local technical support and parts supply
    Our transformers average over 200,000 hours of trouble-free operation with failure rate below 0.5%, ensuring your complete peace of mind.

 

Production Process and Quality Control

Image showcasing the advanced manufacturing and assembly process of a 1250KVA Dry Type Transformer on a modern production line.
Built with Expertise: The Production of Our 1250KVA Dry Transformer. Witness the skilled craftsmanship and controlled environment that goes into building every unit.

Our manufacturing process employs advanced technology and equipment:

  • Winding Process: CNC numerical control winding machines with 0.1mm precision ensure winding consistency

  • Vacuum Casting: Epoxy resin casting in ≤5Pa vacuum environment eliminates bubble formation

  • Heat Treatment: Program-controlled temperature curing ovens with ±2°C temperature accuracy ensure stable insulation performance

  • Assembly Testing: Fully automated assembly production line with 72-hour aging test for every transformer
    We strictly implement ISO9001 quality management system with quality tracking records for each production step ensuring full traceability.

 

Packaging, Transportation, and Installation

Image showing a securely crated and packaged 1250KVA Dry Type Transformer ready for shipment, with flags or labels indicating export countries like USA, Canada, UK, UAE.
Ready for Global Shipping: Your 1250KVA Dry Transformer Securely Packaged. We ensure safe delivery to destinations worldwide, including the USA, Canada, UK, UAE, and beyond.

We provide professional packaging and shipping solutions:

  • Shock-proof Packaging: Steel-wood structure base with internal damping materials ensures transportation safety

  • Moisture Protection: Built-in humidity indicator cards and desiccants for real-time monitoring

  • Handling Protection: Protective covers at critical points prevent damage during lifting

  • Global Delivery: Partnership with world-renowned logistics companies providing door-to-door service (15 days to UK, 20 days to USA, 10 days to Philippines)
    We have successfully delivered products to 500+ global projects with 99.9% intact delivery rate.

 

1250KVA Dry Type Transformer Certifications

Dry Type Transformer certifications including NOA (Environmental, Occupational Health & Safety, Quality Management Systems), CE, and UDEM, ensuring compliance and reliability.
Our Dry Type Transformer is rigorously certified by NOA (ISO 14001, ISO 45001, ISO 9001), CE, and UDEM, guaranteeing superior performance, environmental responsibility, and workplace safety.

Our 1250kVA dry type transformers comply with international standards such as IEC 60076 and IEEE Std C57 series, ensuring safe, reliable, and high-performance operation in commercial and industrial applications.

 

Global Cooperation

Collage of photos featuring the company's management, skilled employees, and international partners and clients collaborating on 1250KVA Dry Type Transformer projects.
The People Behind Your Power Solution: Meet the Team Dedicated to Your 1250KVA Dry Type Transformer Success. From our factory floor to global partnerships, we work together for you.

This photo gallery showcases our dedicated team and global partnerships behind every 1250KVA dry-type transformer. See our engineering experts with 15+ years of experience collaborating with international clients on factory acceptance tests and technical solutions.

These genuine moments demonstrate our multilingual support capabilities and commitment to building lasting relationships – not just delivering products. When you choose our transformer, you gain both superior technology and a reliable partner invested in your long-term success.

FAQ

Q: What is the typical voltage rating for a 1250kVA dry type transformer?
A: Manufacturers commonly supply 1250kVA dry type transformers with primary voltages ranging from 6kV to 35kV, depending on project requirements.

Q: Is a 1250kVA dry type transformer suitable for indoor installation?
A: Yes. Engineers design dry type transformers specifically for indoor environments where fire safety and environmental protection are critical.

Q: How does a 1250kVA dry type transformer differ from an oil immersed transformer?
A: Dry type transformers use air cooling and solid insulation, eliminating oil leakage risks and reducing maintenance needs.

Q: Can a 1250kVA dry type transformer be customized?
A: Manufacturers customize voltage levels, insulation class, and enclosure designs to match specific project and utility requirements.

Need a 1250kVA dry type transformer for your project?


Share your voltage level, installation environment, and standards requirement. Our engineering team will provide a suitable configuration and technical proposal.

Reviews

There are no reviews yet.

Be the first to review “1250KVA Dry Type Transformer”

Your email address will not be published. Required fields are marked *